HEM · Energy Performance Assessment

Home Energy Model Report

7 Riverside Walk, Salford · M15 4SD

Assessment Summary Dashboard

HEM headline metrics & fabric compliance overview

EPC Band
C

EPC Headline Metrics

Fabric PerformanceHeating SystemSmart ReadinessEnergy Cost0255075100

Fabric Compliance

Elements compliant0
Above U-value target7
Total elements7
Primary heatingGas combi boiler
Fuel typeMains gas

⚠ Fossil fuel systems are capped at Band C under HEM:EPC

System Efficiency Comparison

0%25%50%75%100%Hot watersystem

Current vs Potential Performance

Side-by-side comparison after recommended upgrades

Current
D
SAP 63
+24
Potential
B
SAP 87
Fabric Performance
Building envelope energy efficiency (walls, roof, windows, floors)
D
68
B
88
+20
Heating System
Heating system efficiency and emissions. Fossil fuels capped at Band C.
C
72
B
90
+18
Smart Readiness
On-site generation, storage, and smart control capability
E
45
B
83
+38
Energy Cost
Annual energy running cost per m²
D
65
B
87
+22
Current annual cost
£0
Potential annual cost
£0
Save £0/yr

Recommended Upgrades (3)

Replace fossil boiler with air source heat pump
COP 3.0 vs current 90% efficiency
Heating band improvement + fossil fuel cap removed
Upgrade 7 fabric elements to target U-values
External walls (0.39 → 0.30), Party walls (0.26 → 0.20), Roof (0.21 → 0.16), Ground floor (0.23 → 0.18), Exposed floor (0.23 → 0.18), Windows (1.82 → 1.40), External doors (1.82 → 1.40)
Fabric performance band improvement
Add battery storage (10 kWh)
Enables self-consumption of PV generation
Smart readiness band improvement

Score Impact Breakdown

Where improvement investment will have the greatest effect on your EPC rating

Headline Metrics — Ranked by Improvement Potential

Top
Smart Readiness
Band E · 45/100
45
+55 to Band A
55 pts
Energy Cost
Band D · 65/100
65
+35 to Band A
35 pts
Fabric Performance
Band D · 68/100
68
+32 to Band A
32 pts
Heating System
Band C · 72/100
72
+28 to Band A
28 pts

Fabric Element Scores — Pinpoint Insulation Gaps

Roof
0.21 W/m²K
+47
External walls
0.39 W/m²K
+46
Party walls
0.26 W/m²K
+46
Windows
1.82 W/m²K
+46
External doors
1.82 W/m²K
+46
Ground floor
0.23 W/m²K
+45
Exposed floor
0.23 W/m²K
+45

Score = how close each element's U-value is to its Building Regulations target. Red = furthest from target, greatest improvement potential.

Energy System Contributions

Space heating systemGas combi boiler
Fossil fuel — capped at Band C
Solar PV generation3.5 kWp
Contributing to smart readiness24.5/35 pts
Battery storageNone installed
Pair with PV for maximum benefit0/30 pts
Smart controlssmart_thermostat
Upgrade to zoned smart controls for full marks15/25 pts

Highest Impact Opportunities

1
Smart Readiness — 55 points below Band A

On-site generation, storage, and smart control capability

2
Energy Cost — 35 points below Band A

Annual energy running cost per m²

3
Fabric Performance — 32 points below Band A

Building envelope energy efficiency (walls, roof, windows, floors)

4
Heating System — 28 points below Band A

Heating system efficiency and emissions. Fossil fuels capped at Band C.

EPC Headline Metrics

Four-band rating replacing the single A–G EPC under the HEM:EPC framework (coming 2027)

Fabric Performance
D
68/100
Building envelope energy efficiency (walls, roof, windows, floors)
Heating System
C
72/100
Heating system efficiency and emissions. Fossil fuels capped at Band C.
Smart Readiness
E
45/100
On-site generation, storage, and smart control capability
Energy Cost
D
65/100
Annual energy running cost per m²
HEM Score
71
EPC Band
C
CO₂ Emissions
1.9 t/yr
Annual Fuel Cost
—

Dwelling Fabric — Thermal Elements

U-values (W/m²K) per element. Lower U-value = better insulation.

ElementU-valueTargetArea (m²)Compliance
External walls0.390.30—Above target
Party walls0.260.20—Above target
Roof0.210.16—Above target
Ground floor0.230.18—Above target
Exposed floor0.230.18—Above target
Windows1.821.40—Above target
External doors1.821.40—Above target

Energy Systems

Heating, hot water, ventilation, generation, and controls

Space heating
Gas combi boiler
Fuel: Mains gasEfficiency: 90%
Hot water system
Hot water cylinder
Fuel: Mains gasEfficiency: 80%Volume: 150L
Ventilation
Natural (background vents)
Airtightness: 5 m³/h/m²
Cooling
None
Solar PV
Roof-mounted PV
Capacity: 3.5kWpOrientation: South
Battery storage
none
Efficiency: 95%
Smart controls
Smart thermostat