04 — Overheating · Home Energy Model · Deep Dive

Part O & HEM Methodology

A detailed walkthrough of our Part O overheating compliance calculations and Home Energy Model assessment methodology — from property geometry capture through solar gain and free area checks to four-metric HEM scoring.

Assessment Methodology
01

Property Geometry & Data Collection

We capture the geometric and construction data needed for both Part O and HEM calculations — orientation, opening areas, construction types and thermal properties.

  • ▸Room-by-room geometry: floor area, ceiling height, room volume and window/opening positions
  • ▸Orientation captured using compass bearing — critical for solar gain calculations
  • ▸Opening schedule: every window and door recorded with dimensions, type and openable area
  • ▸Construction build-up: wall, roof and floor U-values estimated from construction age and verified with thermography
  • ▸Ventilation strategy: existing extract fans, trickle vents, background and purge ventilation provision
  • ▸Shading factors: external obstructions, overhangs and adjacent buildings that reduce solar gain
02

Part O Solar Gains Check (Simplified Method)

We calculate the solar gains through all glazed openings and compare against the Part O limiting values to determine overheating compliance.

  • ▸Solar gain calculated per opening: G = Area × g-value × Solar Irradiance × Orientation Factor
  • ▸Total solar gain summed for each relevant room and the whole dwelling
  • ▸Limiting solar gain values applied per Part O Table 1.4 based on cross-ventilation availability
  • ▸If total gain ≤ limiting value: compliance demonstrated by simplified method
  • ▸If total gain exceeds limit: mitigation required (reduced glazing, solar control glass, external shading) or dynamic thermal modelling needed
03

Part O Minimum Free Area Check

We verify that openable window areas meet the minimum free area requirements using the discharge coefficient and equivalent area method.

  • ▸Equivalent area (Aeq) calculated for each opening: Aeq = Cd × A_physical
  • ▸Discharge coefficient (Cd) applied based on opening type: top-hung, side-hung, pivot, sliding
  • ▸Minimum free area checked against Part O requirements: typically ≥ 1/20th of room floor area
  • ▸Cross-ventilation path assessed: does air have a clear route from one opening to another?
  • ▸Night-time ventilation capability assessed for bedroom overheating risk
  • ▸If free area insufficient: additional openings or larger openable areas specified
04

HEM Four-Metric Assessment

Properties are assessed against the four Home Energy Model headline metrics, each decomposed into contributing factors for actionable improvement.

  • ▸Fabric performance metric: calculated from element U-values, thermal bridging and air-tightness
  • ▸Heating system metric: efficiency and carbon intensity of the primary heat source modelled against demand
  • ▸Smart readiness metric: capability assessed across energy management, monitoring and demand-side response
  • ▸Energy cost metric: modelled annual energy cost using standardised occupancy and energy price assumptions
  • ▸Each metric benchmarked against the 2027 HEM target values for compliance readiness
  • ▸Gap analysis: difference between current score and target quantified, with measure-level impact breakdown
Calculation Methodology

The formulas behind compliance.

Part O compliance and HEM scoring are both driven by specific calculation methods. Here are the core formulas we apply in every assessment.

Solar Gain
G = A × g × S × F

Where A = glazing area, g = solar transmittance, S = solar irradiance, F = orientation factor.

Equivalent Area
Aeq = Cd × A

Where Cd = discharge coefficient of the opening type, A = physical openable area.

Compliance Check
Σ G ≤ G_lim

Total solar gain across all openings must be less than or equal to the Part O limiting value.

Free Area Check
Aeq ≥ Afloor / 20

Minimum equivalent free area must be ≥ 1/20th of the room floor area for ventilation compliance.

Technical Standards

Standards and references we work to.

Approved Doc O

Building Regs Part O

Overheating mitigation in new residential buildings — the 2021 regulation we assess against.

HEM (2027)

Home Energy Model

The four-metric replacement for EPC methodology, mandated from 2027 for all dwellings.

CIBSE TM59

Overheating Design

Design methodology for assessing overheating risk in homes — referenced for dynamic modelling.

EN 16798

Ventilation Standard

European standard for indoor environmental input parameters for design and assessment.

BS EN 12193

Daylight & Sunlight

Standard for measurement and calculation methods for daylight and sunlight in buildings.

Cd Coefficient

Discharge Coefficient

The flow efficiency factor applied to physical opening areas for equivalent area calculations.

Ready to get started?